.XT:0
.XB:0



                   The IBM PC 6800/01/04/05/09/11 cross assemblers


          GENERAL                                                          
                  The assemblers are named as*.exe where '*' is any of 0,
                  1, h1, 4, 5, HC5, 9, or 11 depending on which one you're
                  using.  Command line arguments specify the filenames to
                  assemble.

                  The assemblers accept options from the command line to be
                  included in the assembly.  These options are the
                  following:

                          l      enable output listing.
                          nol    disable output listing (default).
                          cre    generate cross reference table.
                          s      generate a symbol table.
                          c      enable cycle count.
                          noc    disable cycle count.

                  The command line looks like this :

                          as* file1 file2 ... [ - option1 option2 ...]

                  If this method of passing commands to the assembler is
                  used rather than the OPT pseudo op code, a space should
                  separate the minus sign from the last file name and the
                  first option.  Example:

                          as5 program - l cre

                  This command assembles file 'program' with an output
                  listing and a cross reference table.

                  The `S1' formatted object file is placed in file
                  `filename.S19' (m.out on older versions).  The listing
                  and error messages are written to the standard output.
                  If multiple files are assembled, the 'S1' file will be
                  placed under the first file's name.S19.

                  The listing file contains the address and bytes assembled
                  for each line of input followed by the original input
                  line (unchanged, but moved over to the right some).  If
                  an input line causes more than 6 bytes to be output (e.g.
                  a long FCC directive), additional bytes (up to 64) are
                  listed on succeding lines with no address preceding them.

                  Equates cause the value of the expression to replace the
                  address field in the listing.

                  Equates that have forward references cause Phasing Errors
                  in Pass 2.

                  Expressions may consist of symbols, constants or the
                  character '*' (denoting the current value of the program











                  counter) joined together by one of the operators: +-
                  */%&|^.  The operators are the same as in C:

                          +      add
                          -      subtract
                          *      multiply
                          /      divide
                          %      remainder after division
                          &      bitwise and
                          |      bitwise or
                          ^      bitwise exclusive-or

                  Expressions are evaluated left to right and there is no
                  provision for parenthesized expressions.  Arithmetic is
                  carried out in signed twos-complement integer precision
                  (16 bits on the IBM PC)

                  Constants are constructed with the same syntax as the
                  Motorola MDOS assembler:

                          '      followed by ASCII character
                          $      followed by hexadecimal constant
                          @      followed by octal constant
                          %      followed by binary constant
                          digit  decimal constant


          ERRORS
                  Error diagnostics are placed in the listing file just
                  before the line containing the error.  Format of the
                  error line is:

                     File_name,Line_number: Error -> Description of error
                                 or
                     File_name,Line_number: Warning --- Description of error

                  Errors of the first type in pass one cause cancellation
                  of pass two.  Warnings do not cause cancellation of pass
                  two but should cause you to wonder where they came from.

                  Error messages are meant to be self-explanatory.

                  Finally, some errors are classed as fatal and cause an
                  immediate termination of the assembly.  Generally these
                  errors occur when a temporary file cannot be created or
                  is lost during the assembly. Consult your local guru if
                  this happens.


          DIFFERENCES

                  For indexed addressing, the comma is required before the
                  register; `inc x' and `inc ,x' are not the same.

                  Macros are not supported.  (try M4 or M6)

                  The force size operators ('>' and '<') are implemented
                  for all assemblers.








                  The only pseudo-ops supported are:

                          ORG, FCC, FDB, FCB, EQU, RMB, BSZ, ZMB, FILL,
                          PAGE, END, and OPT.

                  The OPT pseudo-op allows the following operands:

                          nol     Turn off output listing
                          l       Turn on output listing (default)
                          noc     Disable cycle counts in listing (default)
                          c       Enable cycle counts in listing (clear
                                     total cycles)
                          contc   Re-enable cycle counts (don't clear total
                                     cycles)
                          cre     Enable printing of a cross reference
                                     table
                          s       generate a symbol table

                  Some of the more common pseudo-ops are not present:

                          SPC     Use blank lines instead
                          TTL     use `pr' to get headings and page numbers
                          NAM[E]  Did you ever use this one anyway?

                          The above pseudo-ops are recognized, but ignored.

                  ZMB (Zero Memory Bytes) is equivalent to BSZ (Block Store
                  Zeroes). FILL can be used to initialize memory to
                  something other than zero:
                          FILL val,nbytes.

          TARGET MACHINE SPECIFICS

           (as0) 6800:  Use for 6802 and 6808 too.

           (as1) 6801:  You could use this one for the 6800 and avoid LSRD,
                        ASLD, PULX, ABX, PSHX, MUL, SUBD, ADDD, LDD and
                        STD.

                 6301:  Called ash1 (Hitachi 6801).  Same as 6801 except
                        cycle times are reduced and a few new instructions
                        are added: XGDX, SLP, AIM, OIM, EIM, TIM.
                        Convenience mnemonics BSET, BCLR, BTGL, BCHG and
                        BTST are also present which generate appropriate
                        mask values:

                                  BSET 4,dog --> OIM #10,dog

                        Bit manipulation using indexed addressing is
                        specified with a trailing ",x": aim #mask,index,x
                        or btgl 5,index,x.

           (as4) 6804:  The symbols 'a', 'x' and 'y' are predefined as $FF,
                        $80 and $81 respectively.  Also defined as 'A', 'X'
                        and 'Y'.  Because of the 6804 architecture, this
                        means that 'clr x' will work since the x register
                        is just a memory location. To use short-direct
                        addressing, the symbol involved must not be a








                        forward reference (i.e. undefined) and must be in
                        the range $80-$83.

                        Remember that bytes assembled in the range $10-$7F
                        will go into the data space; There is no program
                        space ROM for these locations.

                        The syntax for Register indirect addressing is as
                        follows:
                                  mnemonic [<x>or<y>]
                        an example is:
                                  lda [x]

                        The MVI instruction (move immediate) has its own
                        format :
                                  mvi address,#data
                        where address is an 8-bit address in page zero,
                        and data is the value to be written to specified
                        location.

           (as5) 6805:  There is no 'opt cmos' pseudo, so be careful not to
                        use STOP or WAIT in a program that is destined for
                        an NMOS version of the 6805.  The MUL instruction
                        should also be avoided on all versions of the 6805
                        except the C4.  Cycle times are for the NMOS
                        versions.

           (ashc5) 68HC05:      Cycle times are for the 68HC05.  Otherwise, 
                        this assembler is identical to as5.

           (as9) 6809:  The SETDP pseudo-op is not implemented.  Use the
                        '>' and '<' operators to force the size of
                        operands.

                        For compatibility, CPX is equal to CMPX.

           (as11) 68HC11:  Bit manipulation operands are separated by
                        blanks instead of commas since the 'HC11 has bit
                        manipulation instructions that operate on indexed
                        addresses.


          DETAILS
                  Symbol:  A string of characters with an initial non-
                        digit. The string of characters may be from the
                        set:

                                  [a-z][A-Z]_.[0-9]$

                        ( . and _ count as non-digits ).  The `$' counts as
                        a digit to avoid confusion with hexadecimal
                        constants.  All characters of a symbol are
                        significant, with upper and lower case characters
                        being distinct.  The maximum number of characters
                        in a symbol is currently set at 15.

                        The symbol table has room for at least 2000 symbols
                        of length 8 characters or less.










                  Label:  A symbol starting in the first column is a label
                        and may optionally be ended with a ':'.  A label
                        may appear on a line by itself and is then
                        interpreted as:

                               Label  EQU    *

                  Mnemonic:  A symbol preceded by at least one whitespace
                        character. Upper case characters in this field are
                        converted to lower case before being checked as a
                        legal mnemonic.  Thus `nop', `NOP' and even `NoP'
                        are recognized as the same mnemonic.

                        Note that register names that sometimes appear at
                        the end of a mnemonic (e.g. nega or stu) must not
                        be separated by any whitespace characters.  Thus
                        `clra' means clear accumulator A, but that `clr a'
                        means clear memory location `a'.

                  Operand:  Follows mnemonic, separated by at least one
                        whitespace character.  The contents of the operand
                        field is interpreted by each instruction.

                  Whitespace:  A blank or a tab

                  Comment:  Any text after all operands for a given
                        mnemonic have been processed or, a line beginning
                        with '*' or ';' up to the end of line or, an empty 
                        line or, the remainder of a line after ';' (at 
                        least one space or tab must precede the semicolon 
                        if it is not the first character on the line)


          FILES
                  filename.S19  S-record output file
                  STDOUT        listing and errors (use redirection for
                                   listing file)
                  Fwd_refs      Temporary file for forward references.


          IMPLEMENTATION NOTES
                  This is a classic 2-pass assembler.  Pass 1 establishes
                  the  symbol table and pass 2 generates the code.

                                                          12/11/84 E.J.Rupp


                  The ashc5 assembler was added in December, 1990.  Except 
                  for providing 68HC05 cycle times, ashc5 is identical to 
                  as5.

                  This version of the cross assemblers updated by Greg 
                  Thoman in July, 1990 and includes the correction and 
                  enhancements made by Bruce Olney.
                  
                  Previous version of the cross assemblers ported to the 
                  IBM PC on 4/13/87.
                  
                  The "older versions" mentioned above were ported to the
                  IBM PC on 7/25/85.